新聞動態
緩釋消毒器操作注意事項
發布日期:2018/5/18  瀏覽次數:1079 [返回上一頁]
緩釋消毒器操作規程
Operating procedure for slow-release sterilizer
(1)、設備運行中的檢查:
(1) inspection in the operation of the equipment:
1、操作面板數據是否正常。(溫度,頻率等)
1, the operation panel data is normal. (temperature, frequency, etc.)
2、檢查進氣量是否正常,反應釜液位及反應液顏色是否正常。(保證有充足的反應時間)
2, check whether the intake volume is normal, whether the reaction tank liquid level and the color of the reaction fluid are normal. (ensure that there is sufficient reaction time)
3、檢查計量泵聲音及機溫是否正常有無泄露。
3. Check whether the sound and temperature of the metering pump are normal or not.
4、檢查水浴液位是否正常。
4, check the water bath level is normal.
5、檢查氯化酸鈉及鹽酸罐液位是否正常。(不要低于計量泵中心線)
5, check whether the level of sodium chloride and hydrochloric acid tank is normal. (don't be lower than the center line of the pump)
6、觀察出液管單流閥是否有異物及動作是否靈活。
6, observe whether the liquid pipe single flow valve has foreign bodies and whether the action is flexible.
7、防爆塞是否正常。
7, the explosion-proof plug is normal.
8、出液管溫度是否正常。(不低于35℃)
8, the temperature of the outlet pipe is normal. (not less than 35 degrees C)
(2)、開機:
(2).
1、檢查水浴及反應釜內液位應在1/2處。(液位管)
1. Check the water bath and the level of the reactor should be at 1/2. (liquid level tube)
2、開啟溫控器使水浴溫度升至設定溫度。(50℃左右)
2. Open the thermostat to raise the water bath temperature to the set temperature. (about 50 C)
3、排除計量泵內空氣并校定計量泵(校定應以背壓閥后出液量為準,同時應保持同一機器的兩臺泵計量泵背壓一致)背壓應高于進口最大壓力1bar。
3. To eliminate the air in the metering pump and to calibrate the metering pump (calibration should be based on the back pressure of the back pressure valve, and keep the same machine's two pump backpressure), the back pressure should be higher than the maximum inlet pressure 1bar.
4、調整動力水壓力至穩定狀態,使水射器穩定工作。
4, adjust the dynamic water pressure to stable state, so that the ejector works stably.
5、運行計量泵,并逐步調整至所需流量。
5, run metering pump and gradually adjust to the required flow rate.
6、待運行穩定后調整反應釜處于液位。(保證最少反應時間30分鐘以上)
6, after stable operation, the reactor is in the liquid level. (ensure that the minimum reaction time is more than 30 minutes)
7、觀察反應釜液位管顏色,單流閥工作狀態及出液管溫度是否正常。
7. Observe the color of the liquid level tube of the reactor, whether the working state of the single valve and the temperature of the outlet pipe are normal.
(3)、關機及發生器清沖:
(3), shutdown and generator cleaning:
1、停止計量泵工作。
1, stop the work of metering pump.
2、打開進水閥,稀釋反應釜內反應液濃度將反應釜內濃度降至安全濃度(反應釜內顏色基本無色),關閉進水閥。
2, open the inlet valve, the concentration of the reaction liquid in the dilution reactor reduces the concentration of the reaction kettle to the safe concentration (the color of the reactor is basically colorless) and closes the inlet valve.
3、停止水射器工作。
3. Stop the water ejector.
4、停止水浴加熱。
4, stop the water bath heating.
5、將進氣孔用堵死,從安全塞進水,將反應釜內注滿水浸泡十分鐘,后將水從排污閥排出。
5, block the intake port, plug in water from safety, immerse the reactor with water for ten minutes, then drain the water out of the drain valve.
6、重新進水至反應釜1/2處。(液位管)
6, reinfluent to the reaction kettle 1/2. (liquid level tube)
(4)、原料的配制與添加:
(4), the preparation and addition of raw materials:
氯化鈉:
Sodium chloride:
1、氯化酸鈉配制工作人員應穿戴好防護用具。
1, sodium chloride preparation staff should wear protective equipment.
(防酸堿工作服、護目鏡、口罩、防酸堿手套、長統膠鞋)
(anti acid and alkaline work clothes, goggles, masks, acid and alkali resistant gloves, rubber shoes)
2、配制過程中有嚴禁吸煙及明火。(不許使用摔砸等方法)
2, there is no smoking and open fire in the process of preparation. (not to use wrestling and other methods)
3、配制過程必須按照氯化酸鈉與水按1:2的比例混合。(例如:1公斤氯化酸鈉加2公斤水)
3, the mixing process must be mixed according to the ratio of sodium chloride and water to 1:2. (for example: 1 kg of sodium chloride with 2kg of water)
4、必須保證氯化酸鈉完全溶解。
4, it is necessary to ensure that sodium chloride is completely dissolved.
5、配制后的液體經比重檢測合格后方可抽入原料罐中。(例如:1260kg/m320℃)
5. The prepared liquid can be pumped into the raw material tank after passing the specific gravity test. (for example: 1260kg/m320 C)
上一頁